Seitenansicht 40
ATS Designers Guide 41
1
5
. . . .
ATS1740
15
. . . .
ATS1740
3
. . . .
ATS1740
T
T
T
T
T
T
T
T
Galvanic insulation
1.5kV
L
L
L
Drawing 3-11 Star configuration using ATS1740 insulators.
In case of replacing an older system with Advisor MASTER, the existing bus wiring can
be adapted. In that case, using ATS1470 amplifier/insulator modules, up to 6 branches of
non-twisted, non-shielded 300m cable can be connected.
ATS1743 fibre-optic modules
Using optical fibres for communications gives many possibilities for system expansion.
Creating a star configuration using fibre-optic modules is justified if the star configuration
is both extensive and remote, or if the available bus branch range is not sufficient. In that
case, the modules can be used to expand the range of single branches.
Seitenansicht 40